SQD METSEION92040 ION9000 STANDARD CVM STA
SQD METSEION92040 ION9000 STANDARD CVM STA
Stanion #METSEION92040SQD
MFG #METSEION92040
UPC #3606481352316
Product Overview
The PowerLogic ION9000 is your 24/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 Aµs and record both waveforms and 1/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs of 1 A, 5 A; current class 2, 10, 20 A; Frequency of 20-450 Hz. Wide control power range of 90 to 480 VAC or 110 to 480 VDC. DIN rail mounting with remote display and panel mounting (with back to back adapter), plus 2 display options, further enhance the flexibility and adaptability of the ION9000.
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandSchneider Electric
Accuracy0.1S,0.5S,0.1
Country of OriginCA
Dimensions6.30 in H x 6.30 in W x 5.33 in D
Display TypeRemote LCD/Color Touchscreen
Enclosure TypeIP30/IP65
Frequency Rating50 to 60 Hz
Manufacturer NameSchneider Electric
Voltage Rating90 to 480 VAC
For both supply and demand side applications
- Restore power efficiently while keeping people safe and processes operational
- Ensure safe power recovery while switching utility feeds
- Avoid downtime by understanding root causes of acute or chronic power events, and prevent future occurrences
- Increase lifetime of equipment, mitigating effects of poor power quality
- Demand current I1, I2, I3, I4, I5Peak demand currentsDemand power P, Q, SPeak demand power PM, QM, SMCalculated active and reactive energy (+/- W.h, +/- VAR.h) metering type
- Remote displayRemote display adapterMounting instructionsMounting Hardware provided equipment
- EN 50160 compliance checkingIEEE 519 harmonic limitIEC 61000-4-30 class A compliance reportingIEEE 519 compliance reporting waveform capture total demand distortion total harmonic distortion up to the 63rd harmonic up to the 127th harmonic with software disturbance direction detection dip, swell and transient half cycle data acquisition transient detection (20 s) power quality analysis
- Voltage sags and swellsCurrent sags and swellsVoltageCurrentFrequencyActive and reactive power totalApparent power totalActive and reactive power per phaseApparent power per phasePower factor totalPower factor per phaseActive and reactive energyApparent energyHarmonic distorsion (I THD & U THD) type of measurement
- 100 ms 6 cycles at 60 Hz 120 V AC typical400 ms 24 cycles at 60 Hz 240 V AC typical1200 ms 72 cycles at 60 Hz 480 V AC typical ride-through time
- 3P + N + E type of network
- 800 x 480 pixels display resolution
- 1024 samples/cycle sampling rate
- 01 to 20 A measurement current
- Voltage 5 MOhm)5 external CT 0.3 mOhm) input type
- 57 to 400 V AC 42 to 69 Hz between phase and neutral100 to 690 V AC 42 to 69 Hz between phases measurement voltage
- 20 to 450 Hz frequency measurement range
- 8 digital 30 V AC/60 V DC number of inputs
- Voltage +/- 0.1 %Current +/- 0.1 % measurement accuracy
- 4 digital2 form C relay output number of outputs
PROP65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov|ANSI C12.20ANSI C37.90.1IEC 61000-4-15IEC 61000-4-30IEC 61010-1IEC 61326-1IEC 61557-12IEC 61850IEC 62052-11IEC 62052-31IEC 62053-22IEC 62053-23IEC 62053-24IEC 62586UL 61010-1