SQD 8502SFG2V02S CONTACTOR 600VAC 135AMP
SQD 8502SFG2V02S CONTACTOR 600VAC 135AMP
Stanion #8502SFG2V02SSQD
MFG #8502SFG2V02S
UPC #785901619987
Prop 65
Product Overview
Class 8502 type S magnetic contactors are used to switch heating loads, capacitors, transformers and electric motors where overload protection is separately provided. Type S contactors are available in NEMA sizes 00 to 7 and are designed for operation at 600 V maximum.
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandSquare D™
Coil Power Rating40 hp at 200 VAC, 50 hp at 230 VAC, 100 hp at 460/575 VAC
Coil Voltage110/120 VAC
Connection TypeBox Lug
Contact Rating135 A
Country of OriginMX
Dimensions25.16 in H x 11.26 in W x 9.02 in D
Enclosure TypeNEMA 1
FinishPainted
Frequency Rating50/60 Hz
Manufacturer NameSchneider Electric
MaterialSheet Steel
Number of Poles3
Operating Cycles3 cpm
Operating Temperature0 to 40 deg C
Series8502
Terminal TypeScrew Clamp
Type3-Phase Type S Non-Reversing
Wattage30 kW at 200 V/37 kW at 230 V/37 kW at 460/575 V
For construction, infrastructure, industrial markets, commercial office buildings and building automation, switch heating loads, capacitors, transformer and electric motors where overload protection is provided separately
- A normally open holding circuit contact for 3-wire control is provided as standard
- For flexibility field installable or factory modified accessories include auxiliary contacts, power poles and cover mounted control stations
- Bell crank design promotes superior electrical and mechanical life
- NEMA sizes 00 to 5 are supplied with coils that are designed to operate satisfactorily on line voltages of 85% to 110% of rated voltage
- NEMA sizes 5, 6 and 7 contactors are supplied with a DC coil operated by a solid state rectifier circuit that is powered by an AC source
- Sizes 00 to 2 contactors use a class 9999 SX11 auxiliary contact as the holding circuit contact
- Sizes 3 to 7 contactors use a class 9999 SX6 auxiliary contact as the holding circuit contact
- NEMA type 1 general purpose enclosure
- Used to switch heating loads capacitors, transformers and electric motors where overload protections is provided separately
- 600 VAC system voltage
- Screw clamp terminal connection type
- Without indicator
- 40 hp at 200 VAC, 50 hp at 230 VAC, 100 hp at 460 VAC, 100 hp at 575 VAC, separate control circuit
CE Certified|CSA File LR60905/60905 Class 3211-04|ECCN EAR99|IEC 947-4-1|UL E78351 CCN NLDX|PROP65: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov