Square D™
SQD ABL8RPS24050 UNIV.POWER SUP.1P 24V 5A
Square D™
SQD ABL8RPS24050 UNIV.POWER SUP.1P 24V 5A
Stanion #ABL8RPS24050SQD
MFG #ABL8RPS24050
UPC #785901593683
Product Overview
Square D™ PHASEO™ Regulated Power Supply, Switch Mode, Series: ABL, 100 to 500 VAC Input, 24 VDC Output, 120 W, 5 A, 47/63 Hz, DIN Rail Mount, 2.2 in Width, 4.72 in D, 5.63 in Height,
- Attributes
- Documents
- Item Features
- Standards
BrandSquare D™
Amperage Rating5 A
Country of OriginPH
Depth4.72 in
Frequency Rating47/63 Hz
Height5.63 in
Input Voltage100 to 500 VAC
Manufacturer NameSchneider Electric
Mounting TypeDIN Rail
Output Voltage24 VDC
Power Rating120 W
SeriesABL
TypeSwitch Mode
Width2.2 in
Other
- Vertical operating position
- 85 to 132 VAC, 170 to 550 VAC input voltage limits, 47 to 63 Hz network frequency
- <=30 A at 2 ms inrush current
- 0.51 at 240 VAC, 0.59 at 120 VAC cos phi
- 87 to 100% efficiency, 15.5 W power dissipation
- 24 to 28.8 VAC adjustable output voltage limits
- 1 to 3% line and load regulation
- >=120 ms at 400 VAC, >=20 ms at 100 VAC, >=40 ms at 240 VAC holding time
- 3 x 0.5 to 3 x 4 sq-mm AWG 22 to AWG 12 screw type terminals input connection, connection capacity, 1 x 0.5 to 1 x 4 sq-mm AWG 22 to AWG 12 screw type terminals input ground connection, connection capacity, 4 x 0.5 to 4 x 4 sq-mm AWG 22 to AWG 12 screw type terminals output connection, connection capacity, 1 x 0.5 to 1 x 4 sq-mm AWG 22 to AWG 12 screw type terminals output ground connection, 2 x 2.5 sq-mm removable screw terminal block diagnostic relay, connection capacity
- 6561.68 ft operating altitude
- Series/parallel output coupling
- Class I conforming to VDE 0106-1 overvoltage category
- 1 LED green and red output voltage, 1 LED green, red and orange output current
- 0 to 90% during operation, 0 to 95% in storage relative humidity
- -40 to 158 deg F storage temperature
- EMC conforming to EN 61000-6-1, EMC conforming to EN 61000-6-3, EMC conforming to EN/IEC 61000-6-2, EMC conforming to EN/IEC 61000-6-4, EMC conforming to EN/IEC 61204-3, Safety conforming to EN/IEC 60950-1, Safety conforming to EN/IEC 61204-3, Safety conforming to SELV environmental characteristic
- Manual or automatic reset against overload, protection technology, 30 to 32 VAC, manual reset against overvoltage, protection technology, manual or automatic reset against short-circuits, protection technology, tripping if U < 21.6 V against under voltage, protection technology, automatic reset thermal, protection technology
- 35 x 7.5 mm symmetrical DIN rail, 35 x 15 mm symmetrical DIN rail mounting support
- Between input and ground, between output and ground, between input and output, between outputs dielectric strength
- 1 or 2 phase
UL 508|CSA C22.2 No. 60950-1|EAC|KC|CE|CB|RCM Certified