FLUKE FLUKE- 381 REMOTE DISP 1000A TRMS CLAMP W/
FLUKE FLUKE- 381 REMOTE DISP 1000A TRMS CLAMP W/
Stanion #FLUKE381FLU
MFG #FLUKE-381
UPC #95969537483
Prop 65
Product Overview
The Fluke® 381 does everything you would expect from a clamp meter/and then lets you remove the display for even more flexibility. Now one technician can do jobs that used to require two people. Clamp the Fluke® 381 around a conductor/remove the display and walk across the room to operate controls or remove protective equipment/all while watching real time readings. The iFlex" flexible current probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility/ability to measure awkward sized conductors and improved wire access.
- Attributes
- Documents
- Application
- Includes
- Item Features
- Standards
- Warranty
BrandFluke®
AC Current Accuracy2% +/-5 Digits at 999.9 A, 3% +/-5 Digits at 2500 A
Dimensions10.9 in L x 3.46 in W x 1.69 in H
Display TypeRemovable Wireless
Electrical Ratings999.9 A. 600 VAC, 1000 VDC
Frequency Rating500 Hz
Jaw Capacity34 mm
Manufacturer NameFluke
MaterialHard Plastic
Operating Temperature-10 to 50 deg C
Resistance60 kOhm
Safety RatingCAT IV 600 VAC/CAT III 1000 VAC
Voltage Accuracy1.5% +/-5 Digits at 1000 VAC, 1% +/-5 Digits at 1000 VDC
For clamp meter with remote-display module and detachable iFlex enabling measurements in difficult situations such as a hazardous environments or very tight spaces
(1) 18 in iFlex™ Flexible Current Probe, (5) AA Alkaline Batteries, (1) Coated Instruction Card, (1) Safety Information Sheet, (1) Soft Carrying Case and (1) TL75 Test Lead
- Wireless technology allows the display to be carried up to 30 ft away from the point of measurement for added flexibility without interference with measurement accuracy
- The removable magnetic display can be conveniently mounted where it is easily seen
- IFlex® flexible current probe expands the measurement range to 2500 A AC
- CAT IV 600 VAC/VDC, CAT III 1000 VAC/VDC
- Integrated low pass filter and state-of the art signal processing allows for use in noisy electrical environments while providing stable readings
- Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- Ergonomic design fits in your hand and can be used while wearing protective equipment
- Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- Soft carrying case
- Accuracy - 2% +/-5 digits dc current/1.5% +/-5 digits (20 to 500 Hz) AC voltage/1% +/-5 digits dc voltage/ 1% +/-5 digits resistance
- Resolution - 0.1 A AC current via jaw/0.1 A (
- 2000 m operating altitude, 12000 m storage altitude
- 7.5 mm flexible current probe diameter
- 1.8 m flexible current probe cable length (head to electronics connector)
- Add 0.1 x specified accuracy for each deg C above 28 deg C or below 18 deg C temperature coefficients
- 3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2% for C.F, >2 AC current via jaw/3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2% for C.F, >2 2 AC current via flexible current probe crest factor (50/60 Hz)
- <=30 Ohm measure continuity
- 100 ms measure inrush
- Range 5 to 500 Hz frequency via jaw and flexible current probe, 600 Ohm/6 kOhm/60 kOhm resistance, 2% +/-5 digit (10 to 100 Hz), 5% +/-5 digit (100 to 500 Hz) via jaw, 3% +/-5 digit via flexible current probe AC current accuracy, 1.5% +/-5 digit (20 to 500 Hz) AC voltage, 1% +/-5 digit DC voltage accuracy
EN 61326-1:2006|EN 61326-2-2:2006|ETSI EN 300 328 V1.7.1:2006|ETSI EN 300 489 V1.8.1:2008|FCC Part 15 SubPart C Section 15.207|FCC Part 15 SubPart C Section 15.209|FCC Part 15 SubPart C Section 15.249|FCCID: T68-F381RSS-210 IC: 6627A-F381|ANSI/ISA S82.02.01:2004|CAN/CSA C22.2 File No. 61010-1-04|IEC/EN 61010-1:2001 to 1000 VAC/VDC CAT III/600 VAC/VDC CAT IV|ECCN: 3A992|PROP65: This product is in compliance with Prop65, it is not known to contain any chemicals associated with this regulation
3 years