9013GHG2J53
Product Overview
Telemecanique Pumptrol™ Pressure Switch, Electromechanical, Series: 9013GH, 40 to 170 psi Pressure, 20 to 40 psi Differential, 300 psi Maximum, 2NC Contact Configuration, 5 hp at 575 VAC Contact, 10 cpm Operating Cycles, -33 to 257 deg F, Screw Clamp Connection, Nitrile Diaphragm, Thermoplastic Housing Material, NEMA 1/IP20 Enclosure, 3.44 in W x 3.88 in D x 5.4 in H Dimensions,
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandTelemecanique
Connection TypeScrew Clamp
Contact Configuration2NC
Contact Rating5 hp at 575 VAC
Country of OriginMX
Diaphragm MaterialNitrile
Differential20 to 40 psi
Dimensions3.44 in W x 3.88 in D x 5.4 in H
Enclosure TypeNEMA 1/IP20
Housing MaterialThermoplastic
Manufacturer NameSchneider Electric, YAGEO Corporation
Maximum Pressure300 psi
Operating Cycles10 cpm
Pressure Rating40 to 170 psi
Series9013GH
Temperature Rating-33 to 257 deg F
TypeElectromechanical
Controlling Electrically Driven Water Pumps, Air Compressors, Indoor and General Purpose Applications
- Contacts open on pressure rise
- The class 9013 type G devices cover higher electrical ratings for direct control of motors in pump and compressor applications
- Diaphragm actuated
- 2 NC, snap action, DPST-DB, form YY contacts type and composition
- -22 to 257 deg F air and fresh water controlled fluid
- 1/4 in NPSF internal conforming to UL 508 fluid connection
- Regulation between 2 thresholds, adjustable differential scale
- 4-terminal blocks
- 10 AWG clamping capacity electrical connection
- Nitrile (Buna-N) diaphragm
- 300000 cycles mechanical durability, 100000 cycles at 10 cycles/min electrical durability
- Zinc plated steel or equivalent flange
- 1.5 kW at 115 VAC 1-ph, 2.2 kW at 115 VAC 3-ph, 3.7 kW at 460 VAC 3-ph, 3.7 kW at 460 VAC 1-ph, 3.7 kW at 575 VAC 3-ph, 0.75 kW at 230 VDC, 3.75 kW at 230 VAC 3-ph, 2.2 kW at 230 VAC 1-ph, 0.75 kW at 115 VDC, 3.7 kW at 575 VAC, 1-ph power rating
- General purpose (indoor) environmental conditions
- Bracket mounting
- Standard action
- 3 knockouts for 1/2 in conduit UL508 cable entry
- Noryl thermoplastic resin
- 300 psig system pressure
RoHS Compliant|UL 508 E12158 CCN NKPZ|CSA LR25490 Class 3211 06|CE Marked|NSF ANSI 372|PROP65: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.p65Warnings.ca.gov