LEV AGRBF-W WH AFCI/ST GFCI BLANK FACE LIGHTED
LEV AGRBF-W WH AFCI/ST GFCI BLANK FACE LIGHTED
Stanion #AGRBFWLEV
MFG #AGRBF-W
UPC #78477803325
Product Overview
The SmartlockPro® dual function AFCI/GFCI receptacle offers protection both from electrical fires that could result from arc-faults and from electrical shock due to ground faults in one smart device. Through advanced technology, the SmartlockPro® dual function AFCI/GFCI receptacle helps protect home and family by working to detect arc-fault and ground fault hazards and, if detected, quickly cuts off power to help avoid a potential fire or shock occurrence. The SmartlockPro® dual function AFCI/GFCI receptacle offers a National Electrical Code (NEC) compliant option for AFCI/GFCI protection in residential kitchens and laundry areas for new construction, modifications/extensions and replacement receptacles. It is also ideal as a replacement for ungrounded receptacles, satisfying for both AFCI and GFCI protection.
- Attributes
- Documents
- Application
- Includes
- Item Features
- Standards
- Warranty
BrandLeviton®
Amperage Rating20 A
ColorWhite
Country of OriginCN
Dimensions4.19 in H x 1.73 in W x 1.29 in D
GradeProfessional
Horsepower1 hp
Manufacturer NameLeviton
MaterialPolycarbonate
NEMA RatingNEMA 5-15R/5-20R
Number of Poles2
Number of Wires3
Temperature Rating-35 to 66 deg C
Terminal TypeBack/Side Wire
TypeDual Function Feed-Through Monochromatic Self-Test
Voltage Rating125 VAC
For all Decora® devices and wallplates
Test and Reset Buttons, Mounting Screws, Washers, Instruction Sheets, Self-Ground Clip, Less Wallplate and Wallplate Screws
- May be used for outlet branch circuits where AFCI protection is desired but is located where an outlet is not needed
- Ideal for installing in locations to make AFCI protection readily accessible per NEC® requirements
- May be used on circuits feeding lighting loads as well as other loads such as smoke detectors where a receptacle is not used
- Trip threshold meets or exceeds UL requirements for tripping time on ground faults and on both series and parallel arcs for optimal safety
- On initial power up, tests the GFCI circuit within 3 s
- Patented lockout action prevents reset if the device is damaged
- Status indicator light provides simple, intuitive feedback on power and protection status as well as indication of line/load reversal
- TEST and RESET buttons are readily accessible on the face of the device
- Improved immunity to high frequency noise reduces nuisance tripping
- Superior resistance to electrical surges and over voltages enhancing reliability
- Patented bridge contact design provides individual sets of contacts for receptacle face and downstream receptacles; no power will be delivered to receptacle face if improperly wired
- 1-piece T-design trip latch mechanism provides efficient operation
- Impact-resistant thermoplastic cover and body for durability
- Expanded wiring options with nine back-wire holes (two for each line and load connection plus one for ground with an internal clamp) for easy installation
UL 943 E48360|UL1699.A E342815|ANSI C-73|CSA-C22.2 No. 270-14|CSA-C22.2 No. 144.1-06: File LR-57811|NOM Approved|NEMA WD-6
2 years Limited