WATT-STOPPER DW-100-W DU AL TECH. WALL SWITCH OCC. SENSOR 120/277V WHITE
WATT-STOPPER DW-100-W DU AL TECH. WALL SWITCH OCC. SENSOR 120/277V WHITE
Stanion #DW100WWAT
MFG #DW-100-W
UPC #754182919116
Product Overview
PIR technology senses occupancy by detecting the difference between heat emitted from the human body in motion and the background space. Relying on a clear line-of-sight view, passive infrared sensors make 100% coverage cut off possible. These sensors utilize a unique fresnel lens which divides the coverage area into zone, enhancing detection of small movement. Using the doppler principle, ultrasonic sensors work by bouncing ultrasonic sound waves off objects in an area and measuring the time it takes for the waves to return. Movement by a person in the area causes the sound waves to return at a changed frequency, resulting in a doppler shift and occupancy detection.
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandWattStopper®
ColorWhite
Connection TypeFlying Lead
Control OutputAutomatic On/Off, Manual On/Off
Country of OriginCN
Coverage525 sq-ft
Dimensions2.73 in L x 1.76 in W x 1.83 in H
Lamp TypeFluorescent/Incandescent/LED
Manufacturer NameLegrand
MaterialPlastic
Mounting TypeSurface
Power Rating0 to 1200 W, 1/6 hp
Response Frequency50/60 Hz
Sensor TypePassive Infrared/Ultrasonic
SeriesDW Series
Temperature Rating35 deg C
Time Delay5 to 30 min
TypeDual Technology Single Relay
Viewing Angle180 deg
Voltage Rating120/230/277 VAC
Other
Indoor, Commercial, Offices, Conference Rooms and Lunch/Break Rooms Applications
- Time delay adjustments - 5 to 30 min at minimum, 3 minimum if no activity after 30 s at walk through mode, 5 s for 10 min with dip switch setting at test mode
- High or low (dip switch) PIR adjustment and minimum to maximum (trimpot), OFF ultrasonic adjustment
- 0 to 800 W tungsten or ballast, 1/6 hp motor load limit for each relay at 120 VAC and 0 to 1200 W ballast load limit for each relay at 277 VAC
- Complies with 2011 NEC requirements
- Detection signature analysis eliminates false triggers and provides immunity to RFI and EMI
- Zero crossing for long relay life
- Vandal-resistant lens combines precise coverage with durability
- Choice of manual on or auto-ON operation
- Selectable walk through mode turns lights off 3 min after the room is initially occupied if no motion is detected after the first 30 s
- Test mode allows quick and easy adjustments
- Selectable audible alert for impending shutoff
- In automatic mode, sensor returns automatically to auto-ON after lights are turned OFF manually, ideal for presentations
- Four occupancy logic options give users the ability to customize control to meet application needs
- Optional light level sensing with simple setup
- Service mode allows sensor to operate as a service switch in the unlikely event of a failure
- Sensor coverage tested to NEMA guide publication WD 7-2000
- Compatible with decorator wallplates
- One relay and one on/OFF button
- Magnetic or electronic ballast load type
- Can turn lights off/on based on occupancy
RoHS Compliant|cUL Listed|UL 244A|UL 508