PANDUIT PUR6AV04GR-G COPPER CABLE CAT 6A VARI
Panduit®
PANDUIT PUR6AV04GR-G COPPER CABLE CAT 6A VARI
Stanion #PUR6AV04GRGPAN
MFG #PUR6AV04GR-G
UPC #613056567467
Product Overview
Category 6A/class EA cable shall be constructed of 23 AWG copper conductors with HDPE low smoke zero halogen (LSZH), FEP (CMP) or PE riser (CMR). The copper conductors shall be twisted in pairs and separated by a cross-divider. All four pairs shall be surrounded by a metallic Vari-MaTriX tape cut into segments of varying length and a flame-retardant jacket. The Vari-MaTriX tape shall minimize the cable diameter and suppress the effects of alien crosstalk while retaining UTP electromagnetic interference immunity. The innovative cable design shall provide installation flexibility as cables can be routed in tight bundles through pathways and spaces.
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandPanduit®
Conductor Size23 AWG
Conductor TypeU/UTP Solid Copper
Country of OriginCN
Jacket ColorGreen
Jacket MaterialHDPE
Length1000 ft
Manufacturer NamePanduit
Number of Conductors4 Pairs
Outside Diameter0.26 in
Resistance<9.38 Ohm/328 ft
Temperature Rating-4 to 140 deg F
TypeCat 6a
Voltage Rating80 V
Other
10GBASE-T Ethernet, Data Center I/O Consolidation, Data Center Server Virtualization, Back-Bone Aggregation, Parallel Processing, High Speed Computing and Indoor Applications
- Vari-MaTriX™ technology - Best-in-class cable diameter delivers superior PSANEXT and PSAACRF suppression while retaining UTP EMI immunity
- Interoperable - Compatible with components of the TX6A-SD™ 10Gig™ UTP copper cabling system with MaTriX technology (70 m solution) for increased design flexibility
- Superior headroom warranty provides the highest margins above the industry standard for both electrical and alien crosstalk performance
- Small, round cable design improves fill capacity, cable management, reduces required bend radius and allows efficient use of pathways and spaces
- Extended temperature range allows operation in 75 deg C (167 deg F) to 90 deg C (194 deg F) ambient environment providing error-free performance in high-density cabinets and large cable bundles running PoE+ or PoE++ applications
- Highest density - All testing and headroom based on 48-port/1RU panels
- Descending length cable markings easy identification of remaining cable to reduce installation time and cable scrap
- http://www.panduit.com/heiler/Videos/M-COPUP6AV04--STD-ENG.mp4
ARRA Compliant|ANSI/TIA 568.2-D|BAA Compliant|IEEE 802.3af/802.3at/802.3bt for PoE Applications|RoHS Compliant|UL Listed CMP-LP (0.6A)/CMR-LP (0.5A)|Buy American Act Compliant