XY2CE1A250H7
Product Overview
XY2-CE cable pull switches provide for an emergency stop to be signaled at any point along a cable up to 165 ft L. Typical applications include conveyor systems, packaging, textiles, transfer machines, presses, woodworking equipment and paint lines. Operation is based on the taut cable principle. Cable must be tight and have appropriate tension applied to set or reset the switch. Once cable tension has been set, the device will open the NC positive opening contacts if either the cable is pulled or if it should become slack due to stretching or breakage. Normal stop versions are used where a momentary, non-emergency signal is required at any point along a cable. Cable pull switches are frequently used in place of individual emergency stop pushbuttons around a machine or conveyor. The cost of the cable pull switch and installation is usually less than the cost of installing individual emergency stop stations required to meet codes and standards. As more individual emergency stop pushbuttons are required, using a cable pull device becomes more attractive and cost effective. An added benefit is that the cable pull switch is available continuously along the cable run and is easy for personnel to pull and operate.
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandTelemecanique
ActionSlow-Break
Amperage Rating3/10 A
Contact Configuration1NO-1NC
Contact Rating3 A at 240 VAC, 0.27 A at 250 VDC
Country of OriginMX
Dimensions9.02 in W x 4.13 in D x 5.59 in H
Enclosure TypeIP66
Manufacturer NameSchneider Electric, YAGEO Corporation
MaterialZamak
Number of Poles2
SeriesXY2-CE
Temperature Rating-25 to 70 deg C
Terminal TypeScrew Clamp
TypeLatching Emergency Stop Rope
Voltage Rating240 VAC
Material Handling, HVAC, Crane and Hoist, Manufacturing, Automotive, Food and Beverage, Complex and Special Machines and Industrial Markets Applications
- 3 A at 240 VAC A300, 0.27 A at 250 VDC Q300 contact rating
- Without pilot light
CCC Certified|CE Certified|CSA C22.2 No 14|CSA C22.2 No. 14|ECCN: EAR99|EN/IEC 60204-1|EN/IEC 60947-1|EN/IEC 60947-5-1|EN/IEC 60947-5-1|EN/IEC 60947-5-5|EN/IEC 60947-5-5|EN/ISO 13850|Green Premium|IEC 60068-2-6-5/60068-2-6/60068-2-27-50/60068-2-27|IEC 60529|JIS C 4520|JIS C 852|PROP65: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov|RoHS Compliant|UL 508|UL 508